top of page
Ron GD/ACLS1600

Child ALS training simulation system

GD/ACLS1600 is an advanced child ALS training simulation system. It can simulate real emergency scenes and all the related signs, such as: pupil states, artery pulse, heart rhythm, heart and lung auscultation sound, etc. All the clinical emergency measures such as defibrillation, pacing, CPR, drug therapy, etc. Real clinical emergency instrument can be used on the system. The manikin would show different vital signs according to different rescue measures. Open case editing function allows lecturer edit, required emergency cases according to clinical practice and teaching requirement. Interactive internet features can implement whole students teaching; The instructor can acquire students’ operation data easily and timely give correction and guidance.

PRODUCT FEATURES

Head and neck:

  • Pupil observation, one side is normal, the other side is dilated; the Flash animation displays light reaction and diameter changes of pupils;

  • Simulate airway foreign obstruction: foreign body obstruction in pharynx, main airway obstruction;

  • Carotid artery is available for five-year old child;

  • Respiration mode:Normalbreath, oligopnea, tachypnea, superficial respiration, excessive respiration, Kussmaul’s respiration, Cheyne-stokes respiration, meningitic breathing, sighing breath, irregular gasping, breathing holding;

  • Voice: including crying, laughing, moaning, coughing, gasping and all kinds of complaints, etc;

  • Airway management: realistic mouth, nose, tongue, gum, throat, esophagus, epiglottis, trachea (the diameter of the simulative airway: 9mm); can practice tracheal intubation via mouth, sputum suction; simulate airway foreign body obstruction conditions(pharyngeal and main airway obstruction); can practice tracheal incision; only right lung ventilation due to excessive intubation position.

Chest and abdomen:

  • Manikin organs include: bilateral lungs, stomach, bladder, rectum, bilateral lungs ventilation, liquid can be infused and drained out from bladder and rectum;

  • Simulate spontaneous breathing, chest rise; can perform bilateral, left side , right side chest rise;

  • Bilateral puncture decompression and puncture effusion can be performed;

  • Femoral artery pulse

  • Auscultatory sound: including heart sound, respiratory sound, bowel sound; and the normal heart sound and respiratory sound can be adjusted according to the heart rate and respiratory frequency;

  • Gastric intubation: can perform gastric lavage, gastrointestinal decompression operation; intubation position can be detected via abdominal auscultation; suction of gastric liquid indicates successful intubation;

  • Vital signs monitor: ECG, heart rate, respiratory frequency, BP, body temperature, saturation of blood oxygen, end-tidal partial pressure of CO2, etc; the flash can simulate spasm condition;

  • Simulate skin color: normal, central cyanosis, peripheral cyanosis, mixed cyanosis, pale;

  • Urethral catheterization: can change male/female perineum to practice male/female catheterization;

  • CPR: Support multiple ventilation ways: mouth to mouth, mouth to nose, BVM to mouth; electronic monitoring of airway open, inflation times, frequency, volume and compression times, frequency, position and depth; automatic judgment of artificial respiration and chest compression ratio; English voice prompts during the entire process;

  • AED, defibrillation and pacing: multimedia animation displays AED and defibrillation process

Limbs:

  • Manual BP measuring arm can simulate BP measurement with Korotkff sound;

  • Venous puncture/transfusion: arm vein, femoral vein, dorsal vein of foot

  • Skin care

  • Intramuscular injection: bilateral deltoid , bilateral vastus lateralis;

  • Bone marrow puncture: tibia with obvious body surface symbol, effusion of simulative bone marrow indicates proper puncture operation

Software:

  • Provide various kinds of drug and multiple administration ways: i.v. drops, i.v., hypo., intramuscular injection, anal plug, injection pump, transfusion pump, etc; general dose and usage of each drug is preset; some drugs exist pharmacodynamic physiological reaction;

  • Provide all kinds of auxiliary examination: biochemical report, CT, ultrasound, ECG, etc;

  • Training and examination, ECG identification training, CPR training and examination are available in the system;

  • Simulative cases training and assessment: Provide various clinical cases script

  • Perform PETCO2: confirm tracheal intubation position and monitor the effectiveness of resuscitation operation

A model Standard components:

  • Intelligent ACLS Five-year-old Child Manikin

  • GD/HS7 BP Training Equipment

  • Heart and Lung Auscultation Simulator Set

  • GD/XD1000CECG Generator

  • GD/CC999CDefibrillator Converter

  • BVM, Stethoscope, Laryngoscope, Tracheotomy tube, Infusion set.

  • Emergency System Controller

  • Medical Air Compressor

B model Standard components:

  • Intelligent ACLS One-year-old Child Manikin

  • GD/HS7 BP Training Equipment

  • Heart and Lung Auscultation Simulator Set

  • GD/XD1000CECG Generator

  • GD/CC999CDefibrillator Converter

  • BVM, Stethoscope, Laryngoscope, Tracheotomy tube, Infusion set.

  • Emergency System Controller

  • Medical Air Compressor

 

Optional accessories:

  • Video monitoring equipment

  • Computer

  • Computer control console

  • Rescue operation station

© 2018 SIMED